Form #43219000
Sept 2012
INSTALLATION AND OPERATION INSTRUCTIONS
OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly
read and understood before installing, operating or servicing this heater.
INFRARED RADIANT CERAMIC HEATER
Models: RSCA3, RSCA6, RSCA10
UNVENTED (For Indoor Installation Only)
! INSTALLER: This manual is the property of the owner. Please present this manual
to the owner when you leave the job site.
Improper installation, adjustment, alteration, service, or maintenance can cause
property damage, injury or death. Read the installation, operation and maintenance
instructions thoroughly before installing or servicing this equipment.
In locations used for the storage of combustible materials, signs must be posted to
specify the maximum permissible stacking height to maintain the required clearances
from the heater to the combustibles. Signs must either be posted adjacent to the
heater thermostats or in the absence of such thermostats, in a conspicuous location.
!IMPORTANT: SAVE THIS MANUAL FOR FUTURE REFERENCE.
SPACE-RAY
Post Office Box 36485 (28236) 305 Doggett Street (28203) Charlotte, North Carolina
Phone (704) 372-6391 Fax (704) 332-5843 www.spaceray.com email: info@spaceray.com
NOT FOR RESIDENTIAL USE.
This heater is not approved in any residential application. This includes (but is not
limited to) the home, living quarters, attached garages, etc. Installation in residential
indoor spaces may result in property damage, asphyxiation, and serious injury or
death.
Seitenansicht 0
1 2 3 4 5 6 ... 28 29

Inhaltsverzeichnis

Seite 1 - RSCA3, RSCA6, RSCA10

Form #43219000 Sept 2012 INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully a

Seite 2 - WHAT TO DO IF YOU SMELL GAS:

Form #43219000 Sept 2012 1. Connect to the supply tank or manifold in accordance with the latest edition of National Fuel Gas Code (ANSI Z223.1), and

Seite 3 - 3) GENERAL INFORMATION

Form #43219000 Sept 2012 10) INSTRUCTIONS FOR PRESSURE TEST GAUGE CONNECTION Supply Pressure 1. The installer will provide a 1/8" N.P.T. plugg

Seite 4

Form #43219000 Sept 2012 11) ELECTRICAL CONNECTIONS 1. All electric wiring shall conform to the latest edition of the National Electrical Code (AN

Seite 5

Form #43219000 Sept 2012 FIELD CONNECTION AND THERMOSTAT WIRING DIAGRAMS A. LINE VOLTAGE (120V) THERMOSTAT CONNECTIONS – SINGLE HEATER PER THERMOSTAT

Seite 6

Form #43219000 Sept 2012 E. TYPICAL THERMOSTAT WIRING INSTALLATIONS FOR STANDING PILOT (N1 OR L1 CONTROL) IGNITION SYSTEM 12) VENTILATION Wher

Seite 7 - INSTALLER

Form #43219000 Sept 2012 13) LIGHTING AND SHUTDOWN INSTRUCTIONS STANDING PILOT IGNITION SYSTEM (Ignition Suffix “1”) 1) Turn the dial to “PILOT

Seite 8 - 7) HANGING

Form #43219000 Sept 2012 14) SEQUENCE OF OPERATION The chart below shows the sequence of operation for the normal operating cycle of the heater equi

Seite 9

Form #43219000 Sept 2012 a) Lower the heater to the floor or other suitable working surface. b) Remove the reflector from the reflector mounting pan

Seite 10 - Sept 2012

Form #43219030 Apr-03 18) REPLACEMENT PARTS GUIDE MODELS: RSCA3-(N1, L1) Item No. Part No. Description 1 42129000 Plenum Box Assembly 2 421

Seite 11 - Maximum

Form #43219000 Sept 2012 IMPORTANT:  Please order by Part Number, not by Item Number.  Refer to complete Model Number when ordering.  All repla

Seite 12 - 11) ELECTRICAL CONNECTIONS

Form #43219000 Sept 2012 TABLE OF CONTENTS SECTION DESCRIPTION PAGE SECTION DESCRIPTION PAGE 1) Safety ...

Seite 13

Form #43219000 Sept 2012 MODELS: RSCA3-(N5, L5) Item No. Part No. Description 1 42129000 Plenum Box Assembly 2 42192000 Emitter Kit (includes items

Seite 14 - 12) VENTILATION

Form #43219000 Sept 2012 20

Seite 15

Form #43219000 Sept 2012 MODELS: RSCA6-(N1A, L1) Item No. Part No. Description 1 40714000 Plenum Box Assembly 2 41218000 Emitter Kit (includes items

Seite 16 - 14) SEQUENCE OF OPERATION

Form #43219000 Sept 2012 22

Seite 17 - 16) REPLACING PARTS

Form #43219000 Sept 2012 MODELS: RSCA6-(N5A, L5) Item No. Part No. Description 1 40714000 Plenum Box Assembly 2 41218000 Emitter Kit (includes items

Seite 18 - 18) REPLACEMENT PARTS GUIDE

Form #43219000 Sept 2012 24

Seite 19

Form #43219000 Sept 2012 MODELS: RSCA10-(N5A, L5) Item No. Part No. Description 1 40742000 Plenum Box Assembly 2 41219000 Emitter Kit (includes items

Seite 20

Form #43219000 Sept 2012 26

Seite 21

Form #43219000 Sept 2012 19) WARNINGS CARD This card is furnished with each heater. Additional copies may be ordered under part no. 43344990. 2

Seite 22

Form #43219000 Sept 2012 LIMITED WARRANTY: Gas-Fired Products, Inc., the manufacturer, warrants to the original owner of any Space-Ray

Seite 23

Form #43219000 Sept 2012 1) SAFETY This heater is a self-contained infrared radiant ceramic heater. Safety information required during installation a

Seite 24 - MODELS: RSCA6-(N5A, L5)

Form #43219000 Sept 2012 SAFETY REQUIREMENTS  The heater area must be kept clear and free from combustible materials, gasoline and other flammable

Seite 25

Form #43219000 Sept 2012 This heater is for Indoor Installation only and can be used in Unvented mode. The term Unvented actually means Ind

Seite 26 - MODELS: RSCA10-(N5A, L5)

Form #43219000 Sept 2012 A critical safety factor to consider before installation is the clearances to combustible materials. Clearance to combustible

Seite 27

Form #43219000 Sept 2012 NOTE: The clearance to combustible materials noted above must be maintained at all times and the same clearan

Seite 28 - 19) WARNINGS CARD

Form #43219000 Sept 2012 6) RSCA DIMENSIONS 7) HANGING The heater can be mounted with the reflector horizontal or angled up to 45º from ho

Seite 29

Form #43219000 Sept 2012 8) OPTIONAL PARABOLIC REFLECTOR EXTENSION ASSEMBLY The heater is completely factory assembled and requires no field assembl